SECTION 11. OUTPUT PROCESSING INSTRUCTIONS

PARAM.

DATA

 

NUMBER

TYPE

DESCRIPTION

01:

2

Repetitions

02:

4

Number of bins

03:

2

Form code (0=open form,

 

 

1=closed form)

04:

4

Bin select value input

 

 

location no.

05:

4

Weighted value input

 

 

location no. (0 =

 

 

frequency distribution

 

 

option)

06:

FP

Lower limit of range

07:

FP

Upper limit of range

Outputs Generated:

Number of Bins * Repetitions

*** 77 RECORD REAL TIME ***

FUNCTION

This Instruction stores the current time in Final Storage. At midnight the clock rolls over from 23:59 to 00:00. The day also changes.

If hourly or daily summary data is output, it may be desirable to have the previous day output, since that is when the measurements were made. Entering a 2 for the day code causes the previous day to be output if it is the first minute of the day. Similarly, entering 2 for the hour-minute code causes 2400 instead of 0000 to be output (the next minute is still 0001). When day and hour-minute are both output, a 2 for either code results in the previous day at 2400.

The year is output as 19xx if xx is greater than 85, otherwise it will be output as 20xx. The CR10 will require a PROM update in the year 2085. If year is output along with a 2 option in day or hour-minute, the previous year will be output during the first minute of the new year.

PARAM.

DATA

 

NUMBER

TYPE

DESCRIPTION

01:

4

Enter appropriate TIME

 

 

option code

Outputs Generated: 1 for each time parameter selected

11-6