CR10 OVERVIEW

 

SAMPLE PROGRAM 2

Instruction #

Parameter

 

(Loc:Entry)

(Par#:Entry)

Description

*1

 

Enter Program Table 1

01:60

 

60 second (1 minute) execution interval

Key "#D" until

01:P00

Erase previous Program before

is displayed

 

continuing.

01:P17

01:1

Measure internal temperature

 

Store temp in Location 1

02:P14

 

Measure thermocouple temperature

(differential)

01:1

1 repetition

 

 

02:1

Range code (2.5 mV, slow)

 

03:5

Input channel of TC

 

04:1

TC type: copper-constantan

 

05:1

Reference temp is stored in Location 1

 

06:2

Store TC temp in Location 2

 

07:1

Multiplier of 1

 

08:0

No offset

Instruction #

Parameter

Description

(Loc.:Entry)

Par.#:Entry)

03:P92

 

If Time instruction

 

01:0

0 minutes into the interval

 

02:60

60 minute interval

 

03:10

Set Output Flag 0

The CR10 is programmed to measure the thermocouple temperature every sixty seconds. The If Time instruction sets the Output Flag at the beginning of every hour. Next, the Output Instructions for time and average are added.

04:P77

 

Output Time instruction

 

01:110

Store Julian day, hour, and minute

05:P71

01:1

Average instruction

 

one repetition

 

02:2

Location 2 - source of TC temps. to be

 

 

averaged

Instruction #

Parameter

Description

(Loc.:Entry)

(Par.#:Entry)

06:P92

 

If Time instruction

 

01:0

0 minutes into the interval

 

02:1440

1440 minute interval (24 hrs.)

 

03:10

Set Output Flag 0

07: P77

 

Output Time instruction

 

01:100

Store Julian day

08: P73

 

Maximize instruction

 

01:1

One repetition

 

02:10

Output time of daily maximum in hours and minutes

 

03:2

Data source is Input Storage Location 2.

 

 

OV-19