SECTION 11. OUTPUT PROCESSING INSTRUCTIONS

Code

Result

xxx1

SECONDS (with resolution of 0.125 sec.)

xx1x

HOUR-MINUTE

xx2x

HOUR-MINUTE, 2400 instead of 0000

x1xx

JULIAN DAY

x2xx

JULIAN DAY, previous day during first

 

minute of new day

1xxx

YEAR

Any combination of Year, Day, HR-MIN, and seconds is possible (e.g., 1011: YEAR, HR- MIN, SEC).

*** 78 SET HIGH OR LOW RESOLUTION ***DATA STORAGE FORMAT

FUNCTION

This instruction enables high resolution (5 character) or low resolution (4 character) final data storage format. Instruction 78 should be entered ahead of the output instructions for which the specified resolution is desired. The default format is low resolution. At the beginning of each program table execution, the low resolution format is automatically enabled.

PARAM.

DATA

 

 

NUMBER

TYPE

DESCRIPTION

01:

2

0

= low resolution;

 

 

1

= high resolution

Outputs Generated:

 

0

*** 79 SAMPLE ON MAXIMUM OR ***MINIMUM

FUNCTION

Instruction 79 samples specified input location values at the time a new maximum or minimum value is detected by a previous Maximize (73) or Minimize (74) Instruction. When the Output Flag is set, the values copied to Intermediate Storage are transferred to Final Storage.

Instruction 79 must directly follow the maximum or minimum Instruction to which it refers. If the previous Instruction 73 or 74 has more than 1 repetition, Instruction 79 samples whenever a new maximum or minimum is detected in any of the locations. If sampling is to occur only when a specific input location shows a new maximum or minimum, the previous Maximize or Minimize Instruction should have one rep referring to that input location.

PARAM.

DATA

 

NUMBER

TYPE

DESCRIPTION

01:

2

Repetitions (number of

 

 

sequential locations to

 

 

sample)

02:

4

Starting input location

no.

 

 

Outputs Generated:

1 for each repetition

*** 80 SET ACTIVE STORAGE AREA ***

FUNCTION

Instruction 80 is used to redirect Output data to either of the Final Storage areas or to Input Storage and to set the array ID for Final Storage. At the beginning of each table the Active Output area is set to Final Storage Area 1.

When directed to Final Storage, the second parameter can be used to set the output array ID. Instruction 80 should follow the instruction setting flag 0. If parameter 2 is 0, the array ID is determined by the instruction location number of Instruction 80 or by the instruction that set the Output Flag, whichever comes last. When data are sent to Input Storage, no array ID is sent.

PARAM.

DATA

 

NUMBER

TYPE

DESCRIPTION

01:

2

Storage area option

 

 

00 or 01 = Final

 

 

Storage Area 1

 

 

02 = Final Storage Area 2

 

 

03 = Input Storage Area

02:

4

Starting input location

 

 

destination if option 03

 

 

Output Array ID if options

 

 

0-2 (1-511 are valid IDs)

*** 82 STANDARD DEVIATION IN TIME ***

FUNCTION

Calculate the standard deviation (STD DEV) of a given input location. The standard deviation is calculated using the formula:

S = ((ΣXi2 - (ΣXi)2/N)/N)1/2

where Xi is the ith measurement and N is the number of samples.

PARAM.

DATA

 

NUMBER

TYPE

DESCRIPTION

11-7