metal (w/o a belt) Green Belt Aligner Roller itself. Note that the two metal surfaces are flush.

Step 12: Remove the Green Belt Aligner Roller Assembly by removing the “4” screws.

Important: Leave the Coupler attached.

Assembly Process

Step 13: Stretch the new green belt onto the Aligner Roller Assembly, green side out.

Take care when handling the Aligner Roller Assembly so as not to damage the Flex Coupling.

Rotate the shaft to confirm that the belt tracks properly.

Step 14: Slide the Aligner into place, loosely attach the “4” Pan Head Screws with the “4” Lock Washers.

ROTATE

STRETCH

BELT

Check that the metal surface of the Aligner Roller Assembly is flush with the Sheet Metal surface of the Paper Guide. A 12” metal ruler works well to check this adjustment. Slip the ruler under the green belt and press it flat against the two surfaces. Adjust the Aligner and snug the screws when perfectly flush.

NOTE: The green belt should look like the drawing shown after step 11.