Cellboost 999-823 manual Operating Controls, Keyswitch - Starts and stops the engine

Models: 999-823

1 88
Download 88 pages 11.3 Kb
Page 28
Image 28

Operating Controls

7

8

9

10

2422

7.Engine Choke – Moving the lever to the left sets the choke for easier cold engine starting Moving the lever to the right opens the choke and allows the warmed up engine to run properly.

8.Engine Throttle – Moving the control lever to the left increases the engine speed and moving the lever to the right slows the engine to idle speed.

9.Keyswitch – Starts and stops the engine.

10.Trencher Activation "Operator Presence" Pedal – This pedal must be stepped on and held in the downwards position before the trencher control lever is moved from the center Neutral Lock position. When the operator presence control has be depressed, the trencher activation control lever will be able to be moved into either the Forward or Reverse position, activating the trencher chain. If the operator releases this control pedal, the trencher hydraulic control lever will return to the Neutral position, stopping the trenching operation.

2-6

Page 28
Image 28
Cellboost 999-823 manual Operating Controls, Keyswitch - Starts and stops the engine