VERSAJET
|
|
| [Format] | ASCII | GS ( k pL pH cn fn n | |
| Programming Reference | |||||
|
|
|
| Hex | 1D 28 6B 03 00 30 41 n | |
|
|
|
| |||
|
|
|
| Decimal | 29 | 40 107 3 00 48 65 n |
|
|
| [Range] | (pL + pH x 256) | = 3 (pL =3, pH =0) | |
|
|
|
| cn = 48, fn = 65 |
| |
|
|
|
| 0 ≤ n ≤ 30 |
|
|
|
|
| [Default] | n = 0 |
|
|
|
|
| [Description] | Specifies the number of columns of the data area of PDF417. | ||
|
|
|
| n = 0 specifies auto processing |
When n is not 0, specifies the number of columns of the data area as n code word.
[Notes]
Settings of this function affect the processing of Functions 081 and 082.
When auto processing (n = 0) is specified, the maximum number of columns in the data area is 30 columns.
The following data is not included in the number of columns:
Start pattern and stop pattern.
Indicator code word of left and right.
When auto processing (n = 0) is specified, the number of columns is calculated by the printing area when processing Functions 081.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.