GS ( K <Function 49>

VERSAJET

 

 

 

[Name]

Selects printing density

 

Programming Reference

 

 

 

[Format]

ASCII

GS ( K pL pH fn m

 

 

 

 

 

 

 

Hex

1D 28 4B 02 00 31 m

 

 

 

 

Decimal

29 40 75 2 0 49 m

 

 

 

[Range]

(pL + pH x 256) = 2 (pL = 2, pH = 0)

 

 

 

 

fn = 49, 0 ≤ m ≤ 15

 

 

 

[Default]

m = 8

 

 

 

 

 

[Description]

Selects printing control mode by m.

 

 

 

 

 

 

 

 

 

 

 

m

Function

 

 

 

 

m < 8

Selects pale density

 

 

 

 

 

m = 8

Selects standard density

 

 

 

 

 

m > 8

Selects strong density

 

 

 

 

[Notes]

 

 

 

 

 

 

 

When a standard mode is selected, all the data in a line is printed in the same density.

When a page mode is selected, all the data printed collectively by FF or ESC FF is printed in the same density.