RS t

VERSAJET

Programming Reference

[Name]

Define flash macro

 

[Format]

ASCII

RS t n d1…..dk

 

 

 

Hex

1E 74 n d1…..dk

 

 

Decimal

30 116 n d1…..dk

 

[Range]

1 ≤ n ≤ 8

 

 

[Default]

None

 

 

[Description]

Define flash macro.

[Notes]

Macro definition starts when this command is processed during normal operation and ends when it is processed during macro definition.

While the macro is defined, the printing is also executed.

The maximum data size to be defined as a macro is 8 KB. If the macro definition exceeds the maximum data size, this command will not be processed, and the LED1 indicator blinks red, the LED2 and LED3 indicators blink green, LED4 indicators blinks red (means ‘Command Error’).

The macro is executed by RS u.

If the printer processes this command, it will save the macro definition into flash.

The macro can be executed repeatedly after it is defined.

The defined contents of the macro are not cleared by ESC @.