GS ( k QR Code <Function 167>
VERSAJET
|
|
| [Format] | ASCII | GS ( k pL pH cn fn n | |
| Programming Reference | |||||
|
|
|
| Hex | 1D | 28 6B 03 00 31 43 n |
|
|
|
| |||
|
|
|
| Decimal | 29 40 107 03 00 49 67 n | |
|
|
| [Range] | (pL + pH X 256) | = 3 (pL = 3, pH = 0) | |
|
|
|
| cn = 49, fn = 67 |
| |
|
|
|
| 2 ≤ n ≤ 5 |
|
|
|
|
| [Default] | n = 2 |
|
|
|
|
| [Description] | Specifies the size of a module of QR Code symbol. | ||
|
|
| [Notes] |
|
|
|
Settings of this function affect the processing of Functions 181 and 182.
The setting unit differs, depending on the printer models.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.
n = width of a module = height of a module (Because the QR code modules are square).
The setting unit is 1 dot. The size is set in units of 0.125 mm {1/203 inch}.
102