GS ( k QR Code <Function 167>

VERSAJET

 

 

 

[Format]

ASCII

GS ( k pL pH cn fn n

 

Programming Reference

 

 

 

 

Hex

1D

28 6B 03 00 31 43 n

 

 

 

 

 

 

 

 

Decimal

29 40 107 03 00 49 67 n

 

 

 

[Range]

(pL + pH X 256)

= 3 (pL = 3, pH = 0)

 

 

 

 

cn = 49, fn = 67

 

 

 

 

 

2 ≤ n ≤ 5

 

 

 

 

 

[Default]

n = 2

 

 

 

 

 

[Description]

Specifies the size of a module of QR Code symbol.

 

 

 

[Notes]

 

 

 

Settings of this function affect the processing of Functions 181 and 182.

The setting unit differs, depending on the printer models.

Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.

n = width of a module = height of a module (Because the QR code modules are square).

The setting unit is 1 dot. The size is set in units of 0.125 mm {1/203 inch}.