GS ( k MaxiCode <Function 280>

VERSAJET

 

 

 

[Format]

ASCII

GS ( k pL pH cn fn m d1…dk

 

Programming Reference

 

 

 

 

Hex

1D 28 6B pL pH 32 50 30 d1…dk

 

 

 

 

 

 

 

 

Decimal

29 40 107 pL pH 50 80 48 d1…dk

 

 

 

[Range]

4 ≤ (pL + pH x 256) ≤200 (0 ≤ pL ≤ n, 0≤pH≤0)

 

 

 

 

cn = 50

 

 

 

 

 

fn = 80

 

 

 

 

 

m = 48

 

 

 

 

 

0 ≤d ≤255

 

 

 

 

 

k = (pL + pH x 256) – 3

 

 

 

[Description]

Stores the MaxiCode symbol data (d1...dk) in the symbol save area.

[Notes]

Data stored in the symbol save area by this function is processed by Function 281. The data in the symbol save area are reserved after processing Function 281.

kbytes of d1...dk are processed as the symbol data.

Settings of this function are effective until the following processing is performed:

Function 080 or 180 or 280 or 780 or 880 or 980 is executed

ESC @ is executed

The printer is reset or the power is turned off

109