VERSAJET
|
|
| [Format] | ASCII | GS ( k pL pH cn fn m | |
| Programming Reference | |||||
|
|
|
| Hex | 1D 28 6B 03 00 37 51 m | |
|
|
|
| |||
|
|
|
| Decimal | 29 | 40 107 03 00 55 81 m |
|
|
| [Range] | (pL + pH x 256) | = 3 (pL = 3, pH = 0) | |
|
|
|
| cn = 55 |
|
|
|
|
|
| fn = 81 |
|
|
|
|
|
| m = 48 |
|
|
[Description] | Encodes and prints the Datamatrix symbol data in the symbol save area. |
[Notes] |
|
| If there is any error described below in the data of the symbol save area, it cannot be |
| printed. |
| There is no data (Function 780 is not processed). |
| If [(number of columns × number of rows) < number of code word] when auto |
| processing is specified for number of columns and number of rows. |
| Number of code word exceeds 928 in the data area. |
| This command does not affect printing in standard mode. |
| The following data are added automatically by the encode processing. |
| Start pattern and stop pattern |
Indicator code word of left and right
The descriptor of symbol length (the first code word in the data area)
The error correction code word calculated by modulus 929
Pad codeword
119