VERSAJET
Programming Reference
For ITF (Interleaved 2 of 5) (m = 5, 70) process
Start code and stop code are added automatically.
Check digits are not calculated and added.
For CODEBAR
Start code and stop code are not added automatically. Transmit data including the codes.
Specify the start code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68) at beginning of the data (d1).
Specify the stop code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68) at end of the data (dk or dn).
Start code or stop code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68) cannot be specified in bar code data.
Check digits are not calculated and added.
For CODE93 (m = 72) process
Start code and stop code are added automatically.
Check digits (2 character) are calculated and added automatically.
Special character HRI is processed as follows:
The printer prints an HRI character " " as start and stop character.
The printer prints HRI characters "■ + an alphabetic character" as a control character (unprinted character).
166