GS ( k Code49 <Function 967>

VERSAJET

 

 

 

[Format]

ASCII

GS ( k pL pH cn fn n

 

Programming Reference

 

 

 

 

Hex

1D 28 6B 03 00 39 43 n

 

 

 

 

 

 

 

 

Decimal

29 40

107 3 00 57 67 n

 

 

 

[Range]

(pL + pH x256) = 3

(pL = 3, pH = 0)

 

 

 

 

cn = 57, fn = 67

 

 

 

 

 

1≤ n ≤ 255

 

 

 

 

 

[Default]

n = 2

 

 

 

 

 

[Description]

Specifies the width of narrow element.

 

 

 

[Notes]

 

 

 

Settings of this function affect the processing of Functions 981.

The setting unit differs, depending on the printer models.

Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned off.

The setting unit is 1 dot. The width is set in units of 0.125 mm {1/203 inch}.

128