GS ( k Datamatrix <Function 780>

VERSAJET

 

 

 

Programming Reference

[Format]

ASCII

GS ( k pL pH cn fn m d1…dk

 

 

Hex

1D 28 6B pL pH 37 50 30 d1…dk

 

 

Decimal

29 40 107 pL pH 55 80 48 d1…dk

 

[Range]

4≤ (pL + pH x 256) ≤65535 (0≤pL≤255, 0≤pH≤255)

 

 

cn = 55

 

 

 

fn = 80

 

 

 

m = 48

 

 

 

0 ≤d ≤255

 

 

 

k = (pL + pH x 256) – 3

 

[Description]

Stores the Datamatrix symbol data (d1...dk) in the symbol save area.

 

[Notes]

 

 

 

 

Data stored in the symbol save area by this function are processed by Function 781. The

 

 

data in the symbol save area are reserved after processing Function 781.

 

 

k bytes of d1...dk are processed as symbol data.

 

 

Specify only the data code word of the symbol with this function. Be sure not to include

 

 

the following data in the data d1...dk because they are added automatically by the

 

 

printer.

 

 

 

Start pattern and stop pattern

 

 

Indicator code word of left and right

 

 

The descriptor of symbol length (the first code word in the data area)

 

 

The error correction code word calculated by modulus 929

 

 

Settings of this function are effective until the following processing is performed:

 

 

Function 080 or 180 or 280 or 780 or 880 or 980 is executed

 

 

ESC @ is executed

 

 

The printer is reset or the power is turned off

 

 

 