1-60
Cisco ONS 15454 Reference Manual, R7.0
78-17191-01
Chapter 1 Shelf and Backplane Hardware
1.13 1.13 Filler Card
1.13 Filler Card
Filler cards are designed to occupy empty multiservice and AIC-I slots in the Cisco ONS 15454 (Slots
1 – 6, 9, and 12 – 17). The filler card cannot operate in the XC slots (Slots 8 and 10) or TCC slots (7 and
11). When installed, the filler card aids in maintaining proper air flow and EMI requirements.
Note There are two types of filler cards, a detectable version (Cisco P/N 15454-FILLER) and a non-detectable
version (Cisco P/N 15454-BLANK). The detectable card has the label FILLER on the faceplate. The
non-detectable card has no faceplate label. In Software Release 6.0 and greater, the former card is
detectable through CTC when installed in the ONS 15454 shelf.
Figure 1-40 shows the faceplate of the detectable filler card. The filler cards have no card-level LED
indicators.
20 COM_13 46 N.C.
21 NO_13 47 NO_14
22 N.C. 48 COM_14
23 COM_15 49 N.C.
24 NO_15 50 N.C.
25 N.C. 51 GND1
26 NO_0 52 GND2
Table 1-26 Pin Association for Alarm Output Pins (continued)
AMP Champ
Pin Number Signal Name
AMP Champ
Pin Number Signal Name