4-30
Cisco ONS 15454 Reference Manual, R7.0
78-17191-01
Chapter 4 Optical Cards
4.14 4.14.1 OC192 SR/STM64 IO 1310 Card-Level Indicators
Warning
The laser is on when the optical card is booted. The port does not have to be in service for the laser
to be on.
Statement 293
Figure 4-13 shows the OC192 SR/STM64 IO 1310 faceplate and block diagram.
Figure 4-13 OC192 SR/STM64 IO 1310 Faceplate and Block Diagram
You can install OC192 SR/STM64 IO 1310 cards in Slot 5, 6, 12, or 13. You can provision this card as
part of a BLSR, a path protection, a linear configuration, or as a regenerator for longer span reaches.
The OC192 SR/STM64 IO 1310 port features a 1310-nm laser and contains a transmit and receive
connector (labeled) on the card faceplate. The card uses a dual SC connector for optical cable
termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports
1:1 protection in four-fiber BLSR applications where both span switching and ring switching might
occur.
The OC192 SR/STM64 IO 1310 card detects SF, LOS, or LOF conditions on the optical facility. Refer
to the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card also
counts section and line BIP errors from B1 and B2 byte registers in the section and line overhead.
4.14.1 OC192 SR/STM64 IO 1310 Card-Level Indicators
Table 4-15 describes the three card-level LEDs on the OC192 SR/STM64 IO 1310 card.
Demux
CDR
Flash SRAM
Optical
transceiver
ADC x 8
Demux
BTC
ASIC
STM-64/
OC-192
STM-64/
OC-192
STM-64 / OC192
STM-64 / OC192
SCL
Processor
134367
B
a
c
k
p
l
a
n
e
Mux
CK Mpy
Optical
transceiver Mux SCL
FAIL
ACT
SF
1
Tx
Rx
OC192SR
STM64IO
1310