2-6
Cisco ONS 15454 Reference Manual, R7.0
78-17191-01
Chapter 2 Common Control Cards
2.2 2.2 TCC2 Card
Table 2-7 lists the cross-connect card compatibility for each storage area network (SAN) card. For SAN
card software compatibility, see the “6.1.3 FC_MR-4 Compatibility” section on page 6-4.
2.2 TCC2 Card
Note For hardware specifications, see the “A.4.1 TCC2 Card Specifications” section on page A-10.
The TCC2 card performs system initialization, provisioning, alarm reporting, maintenance, diagnostics,
IP address detection/resolution, SONET section overhead (SOH) DCC/GCC termination, and system
fault detection for the ONS 15454. The TCC2 also ensures that the system maintains Stratum 3
(Telcordia GR-253-CORE) timing requirements. It monitors the supply voltage of the system.
Note The TCC2 card requires Software Release 4.0.0 or later.
Note The LAN interface of the TCC2 card meets the standard Ethernet specifications by supporting a cable
length of 328 ft (100 m) at temperatures from 32 to 149 degrees Fahrenheit (0 to 65 degrees Celsius).
The interfaces can operate with a cable length of 32.8 ft (10 m) maximum at temperatures from –40 to
32 degrees Fahrenheit (–40 to 0 degrees Celsius).
Figure 2-1 shows the faceplate and block diagram for the TCC2 card.
ML100X-8 Yes, in Slots 5, 6, 12, 13 Yes Yes
CE-100T-8 Yes Yes Yes
CE-1000-4 Yes Yes Ye s
1. Requires a 15454-SA-ANSI or 15454-SA-HD shelf assembly.
Table 2-6 Ethernet Card Cross-Connect Compatibility (continued)
Ethernet Cards XCVT Card XC10G Card1XC-VXC-10G Card1
Table 2-7 SAN Card Cross-Connect Compatibility
SAN Cards XCVT Card XC10G Card1
1. Requires SA-ANSI or SA-HD shelf assembly
XC-VXC-10G Card1
FC_MR-4 Yes Yes Ye s