Appendix B Connector and Cable Specifications

Cable and Adapter Specifications

StackWise Cables Minimum Bend Radius and Coiled Diameter

Table B-1specifies the minimum bend radius and coiled diameter for each StackWise cable.

Table B-1

StackWise Cables Minimum Bend Radius and Coiled Diameter

 

 

 

 

Cable Part Number

Cable Length

Minimum Bend Radius

Minimum Coiled Diameter

 

 

 

 

STACK-T2-50CM

1.64 ft (0.5 m)

2.60 in. (66 mm)

5.20 in. (132 mm)

 

 

 

 

 

STACK-T2-1M

 

3.28 ft (1.0 m)

2.60 in. (66 mm)

5.20 in. (132 mm)

 

 

 

 

 

STACK-T2-3M

 

9.84 ft (3.0 m)

3.58 in. (91 mm)

7.17 in. (182 mm)

 

 

 

 

 

StackWise Adapters

A StackWise adapter must be installed in the stacking port to enable stacking. The StackWise cable connects to the StackWise adapter in the stacking port. For switches ordered with stacking, the StackWise adapters are preinstalled.

If the switches are not ordered with stacking, the adapters must be ordered separately and installed. You can order a StackWise adapter as part of a StackWise stacking upgrade kit (part number C3650-STACK-KIT=), that contains two adapters and a 0.5 m StackWise cable..

Locating the StackWise Adapter Serial Number

If you contact Cisco Technical Assistance regarding a StackWise adapter, you need to know the serial number. See Figure B-11to find the serial number.

Figure B-11 Location of the Serial Number on the StackWise Adapter

347806, 781-00796-01

SN: AAANNNNXXXX

Catalyst 3650 Switch Hardware Installation Guide

 

B-6

OL-29734-01

 

 

 

Page 82
Image 82
Cisco Systems 3650 manual StackWise Adapters, StackWise Cables Minimum Bend Radius and Coiled Diameter