B-6
Catalyst 3650 Switch Hardware Installation Guide
OL-29734-01
AppendixB Connector and Cable Specifications
Cable and Adapter Specifications

StackWise Cables Minimum Bend Radius and Coiled Diameter

Table B -1 specifies the minimum bend radius and coiled diameter for each StackWise cable.
StackWise Adapters
A StackWise adapter must be installed in the stacking port to enable stacking. The StackWise cable
connects to the StackWise adapter in the stacking port. For switches ordered with stacking, the
StackWise adapters are preinstalled.
If the switches are not ordered with stacking, the adapters must be ordered separately and installed. You
can order a StackWise adapter as part of a StackWise stacking upgrade kit (part number
C3650-STACK-KIT=), that contains two adapters and a 0.5 m StackWise cable..

Locating the StackWise Adapter Serial Number

If you contact Cisco Technical Assistance regarding a StackWise adapter, you need to know the serial
number. See FigureB-11 to find the serial number.
FigureB-11 Location of the Serial Number on the StackWise Adapter
TableB-1 StackWise Cables Minimum Bend Radius and Coiled Diameter
Cable Part Number Cable Length Minimum Bend Radius Minimum Coiled Diameter
STACK-T2-50CM 1.64 ft (0.5 m) 2.60 in. (66 mm) 5.20 in. (132 mm)
STACK-T2-1M 3.28 ft (1.0 m) 2.60 in. (66 mm) 5.20 in. (132 mm)
STACK-T2-3M 9.84 ft (3.0 m) 3.58 in. (91 mm) 7.17 in. (182 mm)
347806, 781-00796-01
SN: AAANNNNXXXX