when connecting cables.

Warning

To avoid electric shock, do not connect safety extra low voltage (SELV) circuits to

 

telephone network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN

 

ports contain TNV circuits. Some LAN and WAN ports use RJ-45 connectors. Use caution

 

when connecting cables.

 

 

Caution Inline power circuits provide current through the communication cable. Use the Cisco provided cable or a minimum 24 AWG communication cable.

Using an External Power Supply

The following warnings apply when you use the external power supply with the Cisco Unified IP Phone:

Warning

Warning

Warning

Warning

Caution

This product relies on the building's installation for short-circuit (over current) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors).

The device is designed to work with TN power systems.

The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.

The power supply must be placed indoors.

Only use the Cisco specified power supply with this product.

Power Outage

Your accessibility to emergency service through the phone is dependent on the phone being powered. If there is an interruption in the power supply, Service and Emergency Calling Service dialing will not function until power is restored. In the case of a power failure or disruption, you may need to reset or reconfigure equipment before using the Service or Emergency Calling Service dialing.