Cisco Systems CP6921CK9 manual Physical and Operating Environment Specifications

Models: CP6921CK9

1 170
Download 170 pages 52.21 Kb
Page 135
Image 135

A P P E N D I X C

Technical Specifications

The following sections describe the technical specifications for the Cisco Unified IP Phone 6900 Series.

Physical and Operating Environment Specifications, page C-1

Cable Specifications, page C-2

Network and Access Port Pinouts, page C-2

Physical and Operating Environment Specifications

Table C-1shows the physical and operating environment specifications for the Cisco Unified

IP Phone 6900 Series.

Table C-1

Physical and Operating Specifications

 

 

 

Specification

 

Value or Range

 

 

Operating temperature

32° to 104°F (0° to 40°C)

 

 

Operating relative humidity

10% to 90% (non-condensing)

 

 

Storage temperature

14° to 140°F (–10° to 60°C)

 

 

 

Height

 

7.3 in. (18.57 cm)

 

 

 

Width

 

5.8 in. (14.79 cm)

 

 

 

Depth

 

7.1 in. (18.05 cm)

 

 

 

Weight

 

2.2 lb (1.0 kg)

 

 

 

Power

 

100-240 VAC, 50-60 Hz, 0.5 A—when using the AC adapter

 

 

48 VDC, 0.2 A—when using the in-line power over the network cable

 

 

 

Cables

 

Category 3/5/5e for 10-Mbps cables with 4 pairs

 

 

Category 5/5e for 100-Mbps cables with 4 pairs

 

 

Note Cables have 4 pairs of wires for a total of 8 conductors.

 

 

Distance Requirements

As supported by the Ethernet Specification, it is assumed that the maximum cable length

 

 

between each Cisco Unified IP Phone and the switch is 100 meters (330 feet).

 

 

 

Cisco Unified IP Phone 6921, 6941, and 6961 Administration Guide for Cisco Unified Communications Manager 7.1 (SCCP)

 

OL-19025-01

C-1

 