Cisco Systems OL-6157-01 manual No connectivity to SFP, Switch placed in, module is inserted

Models: OL-6157-01

1 82
Download 82 pages 6.53 Kb
Page 51
Image 51
No connectivity to SFP

Chapter 3 Troubleshooting

Diagnosing Common Problems

Table 3-1 Common Connectivity Problems and Their Solutions (continued)

Symptom

Possible Cause

Resolution

 

 

 

No connectivity to SFP

The SFP module was

Remove and reinstall the

module.

installed after the switch

SFP module, and reboot the

 

was powered on.

switch.

 

Note By default, the

Note See the “Connecting to

 

100BASE-FX port is

an SFP Module” section

 

enabled and the SFP

on page 2-12and the

 

module slot is disabled if

Cisco Small

 

an SFP module is not

Form-Factor Pluggable

 

already installed when

Modules Installation

 

the switch is powered on.

Notes (order number

 

 

DOC-7815160=) for

 

 

procedures on removing

 

 

an SFP module.

 

A 100BASE-FX device is

Remove the connection to

 

connected to the switch.

the 100BASE-FX device,

 

 

reinstall the SFP module,

 

 

and reboot the switch.

 

 

 

Switch placed in

Bad or non-Cisco-approved SFP

Remove SFP module from the

error-disabled state after SFP

module.

switch, and replace it with a

module is inserted.

 

Cisco-approved module. Use the

 

 

errdisable recovery cause

 

 

gbic-invalid global

 

 

configuration command to verify

 

 

port status, and enter a time

 

 

interval to recover from the

 

 

error-disable state.

 

 

See the command reference for

 

 

information about the errdisable

 

 

recovery command.

 

 

 

Catalyst 2940 Switch Hardware Installation Guide

 

OL-6157-01

3-3

 

 

 

Page 51