DLP- A523 Discontinue Alarm Suppression
Step7 Click Apply.
Alarms that apply directly to this port will change appearance as described in Step 2. (However, alarms
raised on the entire card will remain raised.) A raised AS-CMD alarm that shows the port as its object
will appear in either alarm window. For example, if you suppressed alarms for Port 1 on the Slot 16
OC-48 card, the alarm object will show “FAC-16-1.
Step8 Return to your originating procedure (NTP).
DLP-A523 Discontinue Alarm Suppression
Caution If multiple CTC sessions are open, discontinuing suppression in one session will discontinue
suppression in all other open sessions.
Step1 To discontinue alarm suppression for the entire node:
a. In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tab.
b. Uncheck the Suppress Alarms check box.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the System object will be cleared
in all views.
Step2 To discontinue alarm suppression for individual cards:
a. In the node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
b. Locate the card that was suppressed in the slot list.
c. Uncheck the Suppress Alarms column check box for that slot.
d. Click Apply.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the slot object (for example,
SLOT-16) will be cleared in all views.
Step3 To discontinue alarm suppression for ports, double-click the card to open the card view and click the
Provisioning > Alarm Profiles > Alarm Behavior tabs.
Step4 Uncheck the Suppress Alarms check box for the port(s) you no longer want to suppress.
Step5 Click Apply.
Purpose This task discontinues alarm suppression and reenables alarm reporting on
a port, card, or node.
Tools/Equipment None
Prerequisite Procedures DLP-A522 Suppress Alarm Reporting, page 22-19
DLP-A60 Log into CTC, page 17-69
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher