22-18
Cisco ONS 15454 Procedure Guide, R7.0
November 2007
Chapter22 DLPs A500 to A599
DLP- A521 Modify Alarm, Condition, and History Filtering Parameters
Step3 In the Show Severity area, click the check boxes for the severities [Critical (CR), Major (MJ), Minor
(MN), or Not-Alarmed (NA)] you want to be reported at the network level. Leave severity check boxes
deselected (unchecked) to prevent those severities from appearing.
When alarm filtering is disabled, all alarms show.
Step4 In the Time area, click the Show alarms between time limits check box to enable it. Click the up and
down arrows in the From Date, To Date, and Time fields to modify what period of alarms are shown.
To modify filter parameters for conditions, continue with Step5. If you do not need to modify them,
continue with Step6.
Step5 Click the filter dialog box Conditions tab (Figure22-7).
Figure22-7 Alarm Filter Dialog Box Conditions Tab
When filtering is enabled, conditions in the Show list are visible and conditions in the Hide list are
invisible.
To move conditions individually from the Show list to the Hide list, click the > button.
To move conditions individually from the Hide list to the Show list, click the < button.
To move conditions collectively from the Show list to the Hide list, click the >> button.
To move conditions collectively from the Hide list to the Show list, click the << button.
Note Conditions include alarms.
Step6 Click Apply and OK.
Alarm and condition filtering parameters are enforced when alarm filtering is enabled (see the
“DLP-A225 Enable Alarm Filtering” task on page19-17), and the parameters are not enforc ed when
alarm filtering is disabled (see the “DLP-A227 Disable Alarm Filtering” task on page19-18).
Step7 Return to your originating procedure (NTP).