22-17
Cisco ONS 15454 Procedure Guide, R7.0
November 2007
Chapter22 DLPs A500 to A599
DLP- A521 Modify Alarm, Condition, and History Filtering Parameters
Note The Default and Inherited special profiles cannot be deleted and do not appear in the Select
Node/Profile Combination for Delete Window.
Step10 Return to your originating procedure (NTP).
DLP-A521 Modify Alarm, Condition, and History Filtering Parameters
Step1 At the node, network, or card view, click the Alarms tab, Conditions tab, or History tab.
Step2 Click the Filter button at the lower-left of the bottom toolbar.
The filter dialog box appears, displaying the General tab. Figure 22-6 shows the Alarm Filter dialog box;
the Conditions and History tabs have similar dialog boxes.
Figure22-6 Alarm Filter Dialog Box General Tab
In the General tab Show Severity box, you can choose which alarm severities will show through the
alarm filter and provision a time period during which filtered alarms show through the filter. To change
the alarm severities shown in the filter, go to Step3. To change the time period filter for the alarms go
to Step 4.
Purpose This task changes alarm and condition reporting in all network nodes.
Tools/Equipment None
Prerequisite Procedures “DLP-A225 Enable Alarm Filtering” task on page19-17
DLP-A60 Log into CTC, page 17-69
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher