22-10
Cisco ONS 15454 Procedure Guide, R7.0
November 2007
Chapter22 DLPs A500 to A599
DLP- A518 Create a New or Cloned Alarm Severity Profile
c. Click the History > Session tab to view the alarm messages raised during the current session.
d. Click the History > Card tab to retrieve all available alarm messages for the card and click
Retrieve.
If you check the Alarms check box, the node’s alarm history appears. If you check the Events check
box, the node’s Not Alarmed and transient event history appears. If you check both check boxes, you
will retrieve node history for both alarms and events.
Note The ONS 15454 can store up to 640 critical alarm messages, 640 major alarm messages,
640 minor alarm messages, and 640 condition messages. When any of these limits is
reached, the ONS 15454 discards the oldest events in that category.
Raised and cleared alarm messages (and events, if selected) appear.
Step5 Return to your originating procedure (NTP).
DLP-A518 Create a New or Cloned Alarm Severity Profile
Step1 To access the alarm profile editor from network view, click the Provisioning > Alarm Profiles tabs.
Step2 To access the profile editor from node view, click the Provisioning > Alarm Profiles >
Alarm ProfileEditor tabs (Figure 22-2).
Purpose This task creates a custom severity profile or clones and modifies the
default severity profile.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-69
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher