Cisco ONS 15454 Procedure Guide, R7.0
November 2007
Chapter22 DLPs A500 to A599
DLP- A553 Upgrade DS1 or DS3-12 Cards in a 1:N or 1:1 Configuration to High-Density Electrical Cards
Step6 Type “CTC_HEAP” in the Variable Name field.
Step7 Type “512” in the Variable Value field.
Step8 Click OK.
Step9 Reboot your PC.
Step10 Return to your originating procedure (NTP).
DLP-A553 Upgrade DS1 or DS3-12 Cards in a 1:N or 1:1 Configuration to High-Density Electrical Cards
Note You cannot have any DS-1 cards installed on the same side of the shelf as the DS3/EC1-48 card when
you finish the low-density to high-density upgrade.
Step1 Complete the "DLP-A60 Log into CTC" task on page 17-68. If you are already logged in, continue with
Step 2.
Step2 According to local site practice, complete the "NTP-A108 Back Up the Database" procedure on page
15-5.
Step3 Determine which low-density card(s) (DS-1, DS-3, DS-3E) you want to upgrade to high-density,
according to slot limitations.
Note For 1:N protection groups, the protect card is installed in Slot 3 on the A side of the shelf and Slot 15 on
the B side. For 1:1 protect groups, working and protect cards can be installed in any traffic slot.
The following limitations apply if you are upgrading a low-density protect card:
The protect card must be in a protection group.
The protect card must not protect any low-density electrical cards in Slots 4, 5, or 6 on the A side
of the shelf (Slots 12, 13, or 14 on the B side).
Purpose This task upgrades low-density electrical cards in a 1:N protection
scheme (where N = 1 or 2) to high-density electrical cards
(DS3/EC1-48, DS1/E1-56). Low-density cards are defined as DS-1 and
DS3-12.
Tools/Equipment DS3/EC1-48 card(s), as needed
DS1/E1-56 card(s), as needed
High-density shelf assembly (15454-SA-HD)
High-density EIA (MiniBNC, UBIC-V, UBIC-H) installed.
Prerequisite Procedures NTP-A17 Install the Electrical Cards, page 2-10
Required/As Needed As needed
Onsite/Remote Onsite
Security Level Provisioning or higher