PA-T3 Port Adapter LEDs
Figure 2-1 LEDs on the PA-T3 Serial Port Adapter—Partial Front View
ENABLED |
|
|
| RCLK | FERF | DS3 SERIAL |
RCVR | XMTR |
| RL | |||
|
|
|
| |||
|
|
| AIS | OOF | LL | H10040 |
|
|
|
|
|
LEDs
The
Figure 2-2 LEDs on the PA-2T3 Serial Port Adapter—Partial Front View
ENABLED |
|
|
| RCLK | FERF |
| RCLK | FERF | DS3 SERIAL |
RCVR | XMTR |
| RL | RL | |||||
|
|
|
|
|
|
| |||
|
|
| AIS | OOF | LL | AIS | OOF | LL | H10063 |
|
|
|
|
|
|
|
LEDs
Table
After system initialization, the Enabled LED goes on, indicating that the port adapter has been enabled for operation.
The following conditions must be met before the
•The port adapter contains a valid microcode version that has been downloaded successfully.
•The port adapter is correctly connected to the VIP2 or Catalyst RSM/VIP2 (Cisco 7000 series and Cisco 7500 series,or Catalyst 5000 series switches) and the midplane and is receiving power in the Cisco router.
•The bus recognizes the port adapter.
If any of these conditions is not met or if the initialization fails for other reasons, the enabled LED does not go on.
Table | LEDs for Uplink Port Status | ||
|
|
|
|
LED | Color | State | Description |
|
|
|
|
ENABLED | Green | On | Indicates that port adapter is ready for operation. |
|
|
| |
Uplink Port Status |
|
| |
|
|
|
|
RCLK | Green | On | Indicates that a receive clock has been detected. |
|
|
|
|
FERF | Yellow | On | Indicates that Framer detected Far End Receive |
|
|
| Failure. |
|
|
|
|
OOF | Yellow | On | Indicates that Framer detected Out of Frame. |
|
|
|
|
AIS | Yellow | On | Indicates that Framer detected Alarm Indication |
|
|
| Signal. |
|
|
|
|
RL | Yellow | On | Indicates that port is in remote loopback mode. |
|
|
|
|