CBM-270 User’s Manual

GS :

[Function]

Starting/Ending macro definition

 

[Code]

<1D> H <3A> H

 

[Outline]

Specifying starting / ending macro definition.

 

Means termination when received while defining a macro.

[Caution]

Maximum content available for macro definition is 2048 bytes. A portion exceeding 2048

 

bytes is not defined.

 

 

Even with ESC @ (initialization of the printer) having been executed, defined content is

 

not cleared. Therefore, it is possible to include ESC @ into the content of macro

 

definition.

 

 

Normal printing operation is carried out even while in macro definition

[Default]

Initially, Macro is not specified.

 

[See Also]

GS ^

 

[Sample Program]

[Print Results]

LPRINT CHR$ (&H1D) ; " : " ; LPRINT "+ − − − +" ; CHR$ (&HA) ;

LPRINT " " ; CHR$ (&HA) ; LPRINT "+ − − − +" ; CHR$ (&HA) ; LPRINT CHR$ (&H1D) ; " : " ; LPRINT CHR$ (&H1D) ; " ^ " ; LPRINT CHR$ (2) ; CHR$ (10) ; LPRINT CHR$ (0) ;

END

Normal Printing during

Macro Definition

Printing during Macro Execution