CBM-270 User’s Manual

 

 

 

 

 

 

 

 

GS C2 n1 n2

 

 

 

 

 

 

[Function]

Setting the numbering counter

 

 

[Code]

<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H<N4><3B>H

 

 

<N5><3B>H

 

 

 

 

<1D>H<43>H<32>H<n1><n2>

 

[Range]

0 n1 255, 0 n2 255

 

 

 

[Outline]

This command sets the numbering (serial number counter) value.

 

 

n1 + n2 × 256 (n1 = remainder, n2 = quotient) becomes a counter value.

 

[Caution]

If the counter is set with this command, a repeat count of the identical counter will be

 

 

cleared. If the counter value is beyond the Range specified with the "GS C1" or "GS C;"

 

 

command, the counter will be initialized.

 

[Default]

Not defined.

 

 

 

[See Also]

GS C0, GS C1, GS c, GS C ;

 

[Sample Program]

 

 

 

[Print Result]

 

 

See the sample program and print result for the GS C1 command on Page 82.

 

GS C; N1; N2; N3; N4; N5;

 

[Function]

Setting the numbering counter mode (B)

 

 

[Code]

<1D>H<43>H<3B>H<N1><3B>H<N2><3B>H<N3><3B>H<N4><3B>H

 

 

<N5><3B>H

 

 

 

 

<N1>, <N2>, <N3>, <N4>, and <N5> are character codes.

 

[Range]

0 N1, N2, N5 65535

0 N3, N4 255

 

[Outline]

This command sets the numbering (serial number counter) mode and a counter value.

 

 

N1

 

 

 

: Counter default

 

 

N2

 

 

 

: Counter final value

 

 

N3

 

 

 

: Counter step value

 

 

N4

 

 

 

: Identical counter print count

 

 

N5

 

 

 

: Counter start value

 

 

N1<N2

: Count-up system

 

 

N1>N2

: Count-down system

 

 

N1

= N2

 

 

 

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

N3

= 0

 

 

: Counter stop

 

 

 

 

 

 

 

or

 

 

 

 

 

 

N4

= 0

 

 

 

 

 

 

 

 

 

 

Page 84
Image 84
Citizen Systems CBM-270 user manual GS C2 n1 n2, GS C N1 N2 N3 N4 N5