CBM-270 User’s Manual

GS C0 m n

[Function]

Setting the numbering print mode

 

[Code]

<1D>H<43>H<30>H<m><n>

 

[Range]

0 m 5

 

 

0 n 5

 

[Outline]

This command sets the numbering

(serial number counter) print mode. m denotes the

 

number of print columns.

 

m = 0

Prints the digits indicated by a numeral. In this case, n has no meaning.

m = 1 to 5

Indicates the maximum number of columns to be printed. If a counter value is larger than

 

this the number of columns set with this command, the printer will print the lower m-digits of

 

the counter value.

 

 

n specifies a printing position within the printing columns.

n = 0

Prints the data right justified. The blank columns are spaced.

n = 1

Prints the data right justified. The blank columns are filled with "0".

n =2

Prints the data left justified. The right blank columns are spaced.

[Caution]

If either m or n has a value beyond their ranges, that setting will become invalid.

[See Also]

GS C1, GS C2, GS c, GS C

 

[Default]

m = 0, n = 0

 

[Sample Program]

 

 

LPRINT CHR$ (&H1D) ; "C0" ;

* CNT

 

LPRINT CHR$ (0) ; CHR$ (0) ;

FOR I=1 TO 5

 

GOSUB * CNT

LPRINT CHR$ (&HID) ; "c" ;

 

LPRINT CHR$ (&H1D) ; "C0" ;

NEXT I

 

LPRINT CHR$ (1) ; CHR$ (0) ;

LPRINT CHR$ (&HA) ;

 

GOSUB * CNT

RETURN

LPRINT CHR$ (&H1D) ; "C0" ;

LPRINT CHR$ (3) ; CHR$ (0) ;

GOSUB * CNT

LPRINT CHR$ (&H1D) ; "C0" ;

LPRINT CHR$ (3) ; CHR$ (1) ;

GOSUB * CNT

LPRINT CHR$ (&H1D) ; "C0" ;

LPRINT CHR$ (3) ; CHR$ (2) ;

GOSUB * CNT

END

[Print Result]

Counts from 1 to 5 at m = 0 and n = 0.

Counts from 6 to 10 at m = 1 and n = 0.

Counts from 11 to 15 at m = 3 and n = 0.

Counts from 16 to 20 at m = 3 and n = 1.

Counts from 21 to 25 at m = 3 and n =2.