CBM-270 User’s Manual
ESC c 5 n
[Function] Enabling/Disabling the panel switches
[Code] <1B> H <63> H <35> H <n>
[Range] 0 n 255
[Outline] Selecting the LF switch valid/invalid.
"n" is valid only in the lowest bit (n0).
"n" bit means the followings.
n0 Condition
0 LF SW valid.
1 LF SW invalid.
[Caution] When the panel switch is disabled with this command, the LF switch is disabled. Therefore,
the paper cannot be fed by operating the LF switch.
[Default] n = 0
[Sample Program]
LPRINT CHR$ (&H1B) ; "c5" ; CHR$ (0) ; •••••••• When enabling the LF switch
LPRINT CHR$ (&H1B) ; "c5" ; CHR$ (1) ; •••••••• When disabling the LF switch
ESC d n
[Function] Printing and feeding the paper by n lines
[Code] <1B> H <64> H <n>
[Range] 0 n 255
[Outline] Prints data inside the buffer and feeds paper by n lines.
Specified line does not remain.
The beginning of the line is to be considered as the next printing start position.
[Default] The initial value is not defined.
[Sample Program]
LPRINT "AAAAA"
LPRINT CHR$ (&H1B) ; "d" ; CHR$ (2) ;
LPRINT "AAAAA" ; CHR$ (&HA) ;
END
[Print Results]