iDP3550/3551 User ’s Manual

ESC "" n "data" CR or LF

[Function]

Defining the message

[Code]

<1B>H <2F>H n "data" CR or LF

[Range]

1 n 10

[Outline]

This command can define up to a 50-byte message in one line. If the value of n is

 

specified beyond the range, the data following n will be treated as the print data.

 

Once the message is defined, it remains valid until it is redefined. The data should end

 

with CR (0DH) or LF (0AH). If the data exceeds 50 bytes, the subsequent data will be

 

treated as the print data.

 

Once the message is defined, it remains valid until it is redefined or the download deletion

 

command (ESC DC2 n1 n2) is executed.

ESC DC3 n

[Function]

Printing the message

[Code]

<1B>H <13>H n

[Range]

1 n 10

[Function]

This command prints a message. If the value of n is specified beyond the range or if

 

nothing is specified to n, the messag e will not be printed.

88

CITIZEN

Page 104
Image 104
Citizen Systems iDP3551, iDP3550 user manual ESC ⁄ n data CR or LF