2-24RAID Array 3000 Pedestal Storage Subsystem Hardware User’s Guide

12 V Supply Voltage

The controller monitors the incoming 12-volt levels and ensures that they are satisfactory for operation. The acceptable voltage levels are listed in

Table 2–9.

 

 

Table 2-9

 

 

Acceptable 12 Volt Levels

 

 

 

 

 

 

State

 

Range

Action

 

 

 

 

 

Normal

 

10.80 to 13.80 V

Normal operation

 

 

 

 

 

Low warning

 

10.20 to 10.80 V

Alarm

 

 

 

 

High warning

 

13.80 to 14.40 V

Alarm

 

 

 

 

Low severe

 

Less than 10.20 V

Off line

 

 

 

 

High severe

 

Greater than 14.40 V

Off line

 

 

 

 

 

Temperature Monitoring

External Temperature

The controller monitors the external operating temperature and ensures that they are satisfactory for controller operation. The acceptable temperature levels are listed in Table 2-10.

Table 2-10

Acceptable External Temperature Levels

State

 

Temperature

 

Action

 

 

 

 

 

Normal

 

< 106ºF (41ºC)

 

Normal operation

 

 

 

 

 

High warning

 

< 106ºF to 126ºF

 

Alarm

 

 

(41ºC to 52ºC)

 

 

 

 

 

 

 

High severe

 

> 133ºF (52ºC)

 

Off line

 

 

 

 

 

Page 58
Image 58
Compaq EK-SMCPO-UG. C01 manual Temperature Monitoring, Supply Voltage, External Temperature