Voltage Monitoring
System Voltage
The controller monitors the incoming system voltage levels and ensures that
they are satisfactory for controller operation. The acceptable voltage levels are
listed in Table 2–7.
Table 2-7
Acceptable System Voltage Levels
State Range Action
Normal 4.80 to 5.25 V Normal operation
Low warning 4.75 to 4.80 V Alarm
High warning 5.25 to 5.30 V Alarm
Low severe Less than 4.75 V Off line
High severe Greater than 5.30 V Off line
Termination Voltage
The controller monitors the incoming termination voltage levels and ensures
that they are satisfactory for controller operation. The acceptable voltage
levels are show n in Table 28.
Table 2-8
Acceptable Termination Voltage Levels
State Range Action
Normal 4.20 to 5.40 V Normal operation
Low warning 4.00 to 4.20 V Alarm
High warning 5.40 to 5.55 V Alarm
Low severe Less than 4.00 V Off line
High severe Greater than 5.55 V Off line