RAID Array Controller 2-23
Compaq Confidential – Need to Know Required
Writer: Bob Young Project: RAID A rray 3000 Pedestal Storage Subsystem Hardware User’s Guide Comments:
Part Number: EK-SMCPO-UG. C01 File Name: c-ch2 RAID Array Controller.doc Last Saved On: 12/4/00 1:51 PM
Voltage MonitoringSystem Voltage
The controller monitors the incoming system voltage levels and ensures that
they are satisfactory for controller operation. The acceptable voltage levels are
listed in Table 2–7.
Table 2-7
Acceptable System Voltage Levels
State Range Action
Normal 4.80 to 5.25 V Normal operation
Low warning 4.75 to 4.80 V Alarm
High warning 5.25 to 5.30 V Alarm
Low severe Less than 4.75 V Off line
High severe Greater than 5.30 V Off line
Termination Voltage
The controller monitors the incoming termination voltage levels and ensures
that they are satisfactory for controller operation. The acceptable voltage
levels are show n in Table 2–8.
Table 2-8
Acceptable Termination Voltage Levels
State Range Action
Normal 4.20 to 5.40 V Normal operation
Low warning 4.00 to 4.20 V Alarm
High warning 5.40 to 5.55 V Alarm
Low severe Less than 4.00 V Off line
High severe Greater than 5.55 V Off line