8-14 AlphaServer GS80/160/320 Users Guide
8.7 SCM Command-Line Interf ace
The system control manager supports setup commands and commands
for managing the sy stem. See Tab le 81. For an SCM commands
reference, see the AlphaServer GS80/160/320 Firmware Reference
Manual.

Table 81 SCM Commands

Command Description
Clear {alert, error} Clears firmware or hardware state (alert).
Clears SDD and TDD error logs (error).
Crash Forces a crash dump at the operating system level.
Disable {alert, remote} Disable system alerts or remote access.
Enable {alert, remote} Enables system alerts or remote access.
Erase Erases the current screen.
Fault Emulates the control panel Fault button.
Halt Halts the operating system.
Hangup Terminates a remote session, disconnecting the
modem.
Help Provides SCM command information
Init Prepares modem to send alerts and receive
incoming calls.
Power Directs the system control man ager to suply power
to the processors, memories, and I/O modules in
the system.
Quit Exits the SCM command-line interpreter and
returns control to the COM1 port.
Reset Resets the system.
Set alert Specifies a string that defines the time to wait for
the remote pager to respond to a dial-out, and a
message to be sent to the remote pager.