Prepare a Copy
For fast path, type smitty copy_pre_array and press Enter.
Otherwise, select Prepare a Copy from theArray Copy Services menu.
The Prepare a Copy menu is displayed:
Prepare a Copy
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
Array to be copied hdisk3
Number of disk drives required 2
Minimum disk drive size required 9.1GB
Verify copy during creation no +
Hot spare selection Default +
RAID copy to be coupled [] +
OR
Disk drives to be coupled [] +
F1=Help F2=Refresh F3=Cancel F4=List
F5=Reset F6=Command F7=Edit F8=Image
F9=Shell F10=Exit Enter=Do
The meanings of the fields are:
Array to be copied
The array that you selected as the source data for the copy.
Number of disk drives required
The number of disk drives that must be coupled to the array to permit a copy
to be performed.
Minimum disk drive size required
The effective size of each member disk drive of the array.Each disk drive that
is coupled to the array must be at least this size. If larger disk drives are
selected, the excess space remains unused.
Verifycopy during creation
If you select yes, all data that is written to the copy is verified before the write
operation completes. This action reduces the possibility that unrecoverable
media errors are found when the copy is uncoupled and read, but increases
the time required to perform the copy operation.
Chapter7. Copying Data from Arrays and from Volume Groups 175
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|