SRN Problem Possible Causes
SSA03 Description: The service aid was unable to open an hdisk.This problem
might have occurred because a disk drive has failed or has been
removed from the system.
Action: Do the actions described here:
1. Usethe Configuration Verification service aid (see Configuration
VerificationService Aidon page 387) to determine the location code
of the SSAadapter to which the hdisk is attached. (For example, if the
location code of the hdisk is 00-03-L, the location code of the SSA
adapter is 00-03.)
2. Runthe Link Verification service aid (see Link Verification Service
Aidon page383) to the SSA adapter.
3. Ifa link failure is indicated by the service aid, go to MAP 2320: SSA
Linkon page 445.
4. Ifno link failures are indicated, run diagnostics in System Verification
mode to each pdisk that is attached to the SSAadapter.
None.
440 Users Guide and Maintenance Information