21. (from step 1)
No spare disk drives are available for an array that is configured for hot spare disk
drives.
a. If the subsystem contains disk drives that have failed, repair those disk drives,
or exchange them for new disk drives (see Exchanging Disk Driveson
page319).
b. Type smitty ssaraid and press Enter.
c. Select Change/Show Use of an SSA Physical Disk.
Are any disks listed as SSA Physical disks that are hot spares?
NO Review with the user the requirement for hot spare disk drives. If the
customer wants hot spare disk drives, one or more disk drives must have
their use changed to Hot Spare Disk.
If the customer does not want hot spare disk drives:
a. Return to the SSARAID Arrays menu.
b. Select Change/Show Attributes of an SSA RAID Array.
c. Change the Enable Use of Hot Spares attribute to No.
YES The following conditions must be met to make a hot spare disk drive
available for use by an array:
vThe hot spare disk drive and the array must be on the same SSAloop
(see Creating a Hot Spare Disk Driveon page 72).
vIf the spare_exact parameter is set to true, the size of the hot spare
disk drive must be the same as the size of the smallest member disk
drive in the array.(See Changing or Showing the Attributes of an SSA
RAIDArrayon page 135 to determine how the hot spare attribute is
set; see Listing the Disk Drives in an SSARAID Arrayon page 109 to
determine the sizes of the disk drives that are in the array.)
vIf the spare_exact parameter is set to false, the size of the hot spare
disk drive must be at least that of the smallest member disk in the
array.
a. Ensure that these conditions have been met.
b. Go to MAP 2410: SSARepair Verificationon page 475 to verify the
repair.
466 Users Guide and Maintenance Information