Remove a Disk From an SSA RAID Array
For fast path, type smitty redssaraid and press Enter.
Otherwise, select Remove a Disk From an SSA RAIDArray from the Change Member
Disks in an SSARAID Array menu.
When the List key is pressed for the Disk to Remove option, the following pop-up
menu is displayed:
Remove a Disk From an SSA RAID Array
Type or select values in entry fields.
Pr --------------------------------------------------------------------------
| Disk to Remove |
| |
| Move cursor to desired item and press Enter. |
| |
| ################################################# |
| # Primary Disks |
* | pdisk0 AC7AA078 04-07-P present 9.1GB |+
| pdisk6 AC7AA8A4 04-07-P present 9.1GB |
| ################################################# |
| # Secondary Disks |
| pdisk9 AC7AD176 04-07-P present 9.1GB |
| pdisk10 AC7AE3C9 04-07-P rebuilding 9.1GB |
| ################################################# |
| # Coupled Disks |
| pdisk11 AC7AE417 04-07-P present 9.1GB |
| pdisk12 AC7AE41C 04-07-P present 9.1GB |
| |
| F1=Help F2=Refresh F3=Cancel |
F1| F8=Image F10=Exit Enter=Do |
F5| /=Find n=Find Next |
F9 --------------------------------------------------------------------------
The status values for coupled disk drives are:
present The disk drive is present and operational.
not_present
The disk drive is missing or has failed.
190 Users Guide and Maintenance Information
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|