REMOVAL OF THE SWITCH PANEL

Quest Juice Training Manual

REMOVAL OF THE SWITCH PANEL

1.Remove (2) screws from behind the right and left flavor tabs and the (2) screws from the front underside of the switch panel assembly.

NOTE: The switch harness is marked 1-4 and the connectors are indexed.

21

3

4

2.Remove (3) screws to replace a dispensing switch, if necessary.

NOTE: If a change of dispensing venue is required (push to portion) Cornelius makes available a complete lower door assembly to expedite this change.

Publication Number: TP00968

- 14 -