REMOVAL OF THE COOLING CABINET

Quest Juice Training Manual

REMOVAL OF THE COOLING CABINET

1.Remove (4) 7/16” nuts from the under side of the cabinet frame. Current productions uses

(2) nuts only.

2.Cut the wire tie from the wire bundle in the rear of the unit, just above the condenser.

3. Disconnect the cooling cabinet wire harness.

4.Remove the insulation from around the inlet and outlet fittings of the heat exchange. Remove the locking clips from the inlet and outlet fittings.

5.Insert the screwdriver blade against the lock- ing ring and pull down on the hose.

Publication Number: TP00968

- 22 -

© 2004, IMI Cornelius Inc.