TRANSFORMER
This is a dual stage transformer with 2 outputs. The purpose of the transformer is to step the line voltage to 26 VAC primary to the electrical box and the VRB and 24 VAC secondary is to light the merchandiser.
Current production transformers are equipped with a thermal overload protection device that will cut out when high temperature or high amperage is detected. THE OVERLOAD RESETS AUTOMATICALLY
Quest Juice Training Manual
Primary wires are Blue
Secondary are Red
WATER INLET SOLENOID
The water inlet solenoid is connected to the incoming water line and is only activated when the dispense button is pressed. The water inlet solenoid prevents backflow and is equipped with a strainer screen that needs to be removed and cleaned once a year.
NOTE: THE INLET SOLENOID COIL IS ACTIVED FROM THE VRB BOARD USING THE 28VDC.OUTPUT AN AC COIL WILL NOT WORK IN THIS APPLICATION.
DOOR SWITCH - 72 B SERIAL NUMBER
The door switch on the 72B serial number units is a combination of a door latch and switch. The primary function of the door switch is to inter- rupt the 26 VAC coming into the VRB board when refilling the concentrate. By cutting this voltage the refill lights are reset automatically.
NOTE: WHEN THE DOOR IS OPEN THE DIS- PENSE CIRCUIT IS INOPERABLE DO NOT ATTEMPT TO DEFEAT THIS WITH ANY- THING. BUT THE