DOOR SWITCH - 72 E SERIAL NUMBER

Quest Juice Training Manual

DOOR SWITCH - 72 E SERIAL NUMBER

On or before April 1, 2004 the door switch con-

figuration will be changed to separate the reset Reset Switch in Top of Door switch from the catch. The serial number for

this will have a prefix of 72 D for Quest 4 flavor and 72C for Quest 2 flavor.

Kit #720911146 is available to convert field units to this configuration. The sold-out feature however will be inoperable with the use of this kit.

PLATFORM COMPONENTS

Water Valve/Flow Control

New Door Latch Configuration

The flow control is a ceramic spool and sleeve. It must move freely to regulate the water flow and maintain brix.

Be sure the o-ring is in place and sealing prop- erly.

Sleeve

Spool

Spring

Adjustment Screw

Bottle Adaptor - O-rings

When doing any assembly work on the bottle adaptor be sure to use a small amount of lubri- cant on each o ring This should be a food approved non petroleum based grease.