CY8C22x13 Final Data Sheet | 3. Electrical Specifications |
|
|
3.3.8DC Programming Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and
Table 3-14. DC Programming Specifications
| Symbol | Description | Min |
| Typ | Max | Units | Notes | |
IDDP | Supply Current During Programming or Verify | – | 5 |
| 25 | mA |
| ||
VILP | Input Low Voltage During Programming or Verify | – | – |
| 0.8 | V |
| ||
VIHP | Input High Voltage During Programming or Verify | 2.2 | – |
| – | V |
| ||
IILP | Input Current when Applying Vilp to P1[0] or P1[1] During | – | – |
| 0.2 | mA | Driving internal | ||
|
| Programming or Verify |
|
|
|
|
|
| |
IIHP | Input Current when Applying Vihp to P1[0] or P1[1] During | – | – |
| 1.5 | mA | Driving internal | ||
|
| Programming or Verify |
|
|
|
|
|
| |
VOLV | Output Low Voltage During Programming or Verify | – | – |
| Vss + 0.75 | V |
| ||
VOHV | Output High Voltage During Programming or Verify | Vdd - 1.0 | – |
| Vdd | V |
| ||
FlashENPB | Flash Endurance (per block) | 50,000 | – |
| – | – | Erase/write cycles per block. | ||
FlashENT | Flash Endurance (total)a | 1,800,000 | – |
| – | – | Erase/write cycles. | ||
FlashDR | Flash Data Retention | 10 | – |
| – | Years |
| ||
|
|
|
|
|
|
|
|
|
|
a.A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1 blocks of 50,000 maximum cycles each, 36x2 blocks of 25,000 maximum cycles each, or 36x4 blocks of 12,500 maximum cycles each (and so forth to limit the total number of cycles to 36x50,000 and that no single block ever sees more than 50,000 cycles).
For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to the temperature argument before writing. Refer to the Flash APIs Application Note AN2015 at http://www.cypress.com under Application Notes for more information.
June 3, 2004 | Document No. | 21 |
[+] Feedback