CY8C22x13 Final Data Sheet

3. Electrical Specifications

 

 

3.4.4AC Digital Block Specifications

The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and -40°C TA 85°C, or 3.0V to 3.6V and -40°C TA 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and are for design guidance only or unless otherwise specified.

Table 3-19. AC Digital Block Specifications

 

Function

Description

Min

 

Typ

Max

Units

Notes

Timer

Capture Pulse Width

50a

 

ns

 

 

 

Maximum Frequency, No Capture

 

49.2

MHz

4.75V < Vdd < 5.25V.

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Frequency, With Capture

 

24.6

MHz

 

 

 

 

 

 

 

 

 

 

 

Counter

Enable Pulse Width

50a

 

ns

 

 

 

Maximum Frequency, No Enable Input

 

49.2

MHz

4.75V < Vdd < 5.25V.

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Frequency, Enable Input

 

24.6

MHz

 

 

 

 

 

 

 

 

 

 

 

Dead Band

Kill Pulse Width:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Asynchronous Restart Mode

20

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

Synchronous Restart Mode

50a

 

ns

 

 

 

Disable Mode

50a

 

ns

 

 

 

Maximum Frequency

 

49.2

MHz

4.75V < Vdd < 5.25V.

 

 

 

 

 

 

 

 

 

 

CRCPRS

Maximum Input Clock Frequency

 

49.2

MHz

4.75V < Vdd < 5.25V.

(PRS Mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRCPRS

Maximum Input Clock Frequency

 

24.6

MHz

 

(CRC Mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPIM

Maximum Input Clock Frequency

 

8.2

MHz

 

 

 

 

 

 

 

 

 

 

 

SPIS

Maximum Input Clock Frequency

 

4.1

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

Width of SS_ Negated Between Transmissions

50a

 

ns

 

Transmitter

Maximum Input Clock Frequency

 

16.4

MHz

 

 

 

 

 

 

 

 

 

 

 

Receiver

Maximum Input Clock Frequency

16

 

49.2

MHz

4.75V < Vdd < 5.25V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. 50 ns minimum input pulse width is based on the input synchronizers running at 24 MHz (42 ns nominal period).

June 3, 2004

Document No. 38-12009 Rev. *E

27