Call Filter – Check Enable to activate the Call Filter function. Assign a start filter set for Call Filter.

Data Filter – Check Enable to activate the Data Filter function. Assign a start filter set for Data Filter.

Log Flag – For troubleshooting purpose, you need to specify the filter log here.

None - The log function is inactive.

Block - All blocked packets will be logged.

Pass - All passed packets will be logged.

No Match - The log function will record all packets that are unmatched.

Note: The filter log will be displayed on the Telnet terminal when you type the "log -f" command.

MAC Address for Packet Duplication – Logged packets may also be logged to another location via Ethernet. If you want to duplicate logged packets from the router to another network device, you must enter the MAC address (HEX Format) of the other devices. Enter "0" to disable the feature. It will be helpful under Ethernet switch environment.

Editing the Filter Sets

Comments – Enter filter set comments/description. Its maximum length is 22 characters.