Symbologies
GS1 DataBar Expanded / Expanded Stacked — continued
Length Control
Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.
Configuring Fixed Length Decoding:
1.Scan the START/END bar code.
2.Scan the Fixed Length Decoding bar code.
3.Scan the START/END bar code.
4.Set Length 1 to the first fixed length by following the GS1 DataBar Expanded Length 1,
below.
5.Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by fol- lowing the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1.Scan the START/END bar code.
2.Scan the Variable Length Decoding bar code.
3.Scan the START/END bar code.
4.Set Length 1 to the first variable length by following the GS1 DataBar Expanded Length 1,
below.
5. Set Length 2 to the second variable length by following the GS1 DataBar Expanded Length below.
START / END
PROGRAMMING bar codes
Variable Length Decoding
DEFAULT
Fixed Length Decoding
104 | MagellanTM 3200VSi |