Interface Related Features

Single Cable RS-232 Use ETX

Enables/disables the ability of the scanner to use ETX.

START / END

PROGRAMMING bar codes

Disable ETX

Enable ETX

DEFAULT

Set Single Cable RS-232 ETX Character

Allows selection of the ETX character.

To specify the ETX Character:

1.Scan the START/END bar code.

2.Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.

3.Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual. ASCII parameters must be input by scanning decimal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a single character value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any decimal value from 001 to 127.

4.The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned.

SET SINGLE CABLE RS-232 ETX CHARACTER

62

MagellanTM 3200VSi

Page 70
Image 70
Datalogic Scanning 3200VSI manual Single Cable RS-232 Use ETX, Set Single Cable RS-232 ETX Character