Interface Related Features

RS-232 Interface Features — cont.

ACK Character

START / END

PROGRAMMING bar codes

Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE: 006

Set ACK Character

NAK Character

START / END

PROGRAMMING bar codes

Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing your desired character. Exit programming mode by again scanning the “START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE: 021

Set NAK Character

54

MagellanTM 3200VSi

Page 62
Image 62
Datalogic Scanning 3200VSI manual ACK Character, NAK Character