Error Codes

USB Connection — Connect the scanner to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 1.

 

USB installations may require a power connection via an approved A/C

 

Adapter as shown in Figure 1b or Figure 1c. For example, this would be

 

the case if the scanner is connected along with a number of other devices

NOTE

to a non-powered USB hub.

 

IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor- rect IBM cable. Reference Figure 1.

Keyboard Wedge Connection — Before connection, turn off power to the terminal/PC. The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 1a.

Error Codes

If an error is detected, the scanner will sound a long low tone (for three seconds) and flash its LED, indicating a failure. When this occurs, press the Scanner Pushbutton to hear the error code. If it is configured to do so, the scanner will sound a series of beeps corresponding to the error code and/or flash its LED simultaneous to the beeps. The table below describes what these codes mean and what action should be taken for each.

NUMBER OF

 

 

LED FLASHES/

ERROR

CORRECTIVE ACTION

BEEPS

 

 

 

 

 

1

Configuration

 

 

 

 

2

Interface PCB

 

 

 

 

6

Main PCB

 

 

 

 

10

Button Error

Contact Helpdesk for assistance

 

 

 

12

Imager Module

 

 

 

 

13

Software ID Failure

 

 

 

 

14

Software Fatal Fault

 

 

 

 

Product Reference Guide

3

Page 11
Image 11
Datalogic Scanning 3200VSI manual Error Codes